Build your first workspace

This tutorial builds a small cold-room monitor. You will create a workspace, add an editable temperature and setpoint, calculate the difference between them, and make a report. You do not need a controller or Modbus connection.

You need an Overvis HMI account with permission to create a workspace. Allow about 20 minutes.

  1. Sign in and open the Workspaces menu in the header.
  2. Select Create workspace.
  3. Name it Cold room tutorial and submit the form.
  4. Open Setup, then Parameters.

The workspace is the container for its connections, parameters, dashboards, files, and reports. You are its owner because you created it.

  1. Select Add, then Root branch.
  2. Name the branch Cold room.
  3. Save it.

A branch groups related parameters. It does not communicate with equipment.

  1. Select Add, then Parameter.
  2. Choose the Cold room branch.
  3. Set Name to Temperature and Units to °C.
  4. Choose Constant as the source.
  5. Set the key to tutorial-temperature and allow writes.
  6. Choose a numeric value type that accepts decimal values.
  7. Set Background reading period (seconds) to 10.
  8. Save the parameter.

A constant parameter stores a value in the workspace, so it is useful for learning and for values that do not come from equipment. Give it its first value:

  1. Select Temperature and click Read, keeping Live off. The constant has no value yet, so the row shows Decode error and a Write value link.
  2. Click Write value, enter 4.5, and press Enter.

From now on, click the displayed value to change it.

Repeat the same process with these values:

FieldValue
NameSetpoint
Units°C
SourceConstant, writable
Keytutorial-setpoint
Background reading period10 seconds

Save the parameter and give it its first value the same way: select it, click Read with Live off, click Write value in the Setpoint row, enter 3.0, and press Enter. Constant values are written from the parameter tree after the parameter exists. The create form does not have an initial-value field. You can enable Live afterwards to watch readings; turn it off before editing a value.

  1. Add another parameter to Cold room.
  2. Name it Above setpoint and set its units to °C.
  3. Choose Calculated as the source.
  4. Add Temperature as input 1 and Setpoint as input 2.
  5. Enter the formula #1 - #2 and choose a floating-point result type.
  6. Choose a compatible numeric value type, set the background reading period to 10, and save.

The live value should be 1.5. Change Temperature or Setpoint and confirm that the calculated value follows it. Calculated parameters are read-only.

The Cold room branch with live values; the OB-215 branch comes from the last tutorial

  1. Select Temperature, Setpoint, and Above setpoint in the parameter tree.
  2. Select Quick report.
  3. Choose a time range that includes your changes.

Wait at least 20 seconds before opening the report. Background reading runs independently of the Live switch and stores a point every 10 seconds for these tutorial parameters. If the report is empty, reopen each parameter and confirm its background reading period is 10 rather than empty.

A history report with example parameter data

You now have a working workspace whose values do not depend on equipment. Continue with Build a cold-room dashboard, or learn how parameters work.